-20%
Noshok 110-12-4-615-1-58-6-36 ASME-BPE Sanitary Clamp Pressure Transmitters
NOSHOK List price: $760.07
Noshok 110-12-4-615-1-61-4-8 ASME-BPE Sanitary Clamp Pressure Transmitters
NOSHOK List price: $688.73
Noshok 110-12-4-615-1-61-1-14 ASME-BPE Sanitary Clamp Pressure Transmitters
Part Number:
110-12-4-615-1-61-1-14
Online Prices
NOSHOK List price: $981.09 Original price was: $981.09.$784.52Current price is: $784.52.
Noshok 110-12-4-615-1-61-1-14 ASME-BPE Sanitary Clamp Pressure Transmitters
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2
Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position.
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire |
Pressure ranges | Vacuum through 0 psig to 400 psig |
Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ±0.2% full scale for 1 year, non-accumulating |
Adjustment | ±10% full scale for zero and span |
Response time | < 10 ms |
Service life | > 100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) |
Load limitations | ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 Ω for 1 Vdc to 5 Vdc output ≤ 10,000 Ω for 0 Vdc to 10 Vdc output ≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output |
Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
Measuring element | 316 stainless steel |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP65 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, overvoltage and short circuit protection |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 15 g’s according to IEC 60068-2-6 |
Weight | Approximately 1.1 lb. |
Description
Noshok 110-12-4-615-1-61-1-14 ASME-BPE Sanitary Clamp Pressure Transmitters
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2
Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position.
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire |
Pressure ranges | Vacuum through 0 psig to 400 psig |
Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ±0.2% full scale for 1 year, non-accumulating |
Adjustment | ±10% full scale for zero and span |
Response time | < 10 ms |
Service life | > 100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) |
Load limitations | ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 Ω for 1 Vdc to 5 Vdc output ≤ 10,000 Ω for 0 Vdc to 10 Vdc output ≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output |
Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
Measuring element | 316 stainless steel |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP65 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, overvoltage and short circuit protection |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 15 g’s according to IEC 60068-2-6 |
Weight | Approximately 1.1 lb. |