NOSHOK PT40-750psig-2-2-10-36-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 750 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, G 1/4 B EN 837, integral cable 3 ft, integral orifice, Certified Calibration

Part Number: PT40-750psig-2-2-10-36-ST8-CC
Online Prices

NOSHOK List price: Original price was: $693.93.Current price is: $560.20.

Need Other Pressure ranges ??Please call us 1-888-509-0111
Warranty: 3 YEARS
NEED TO PURCHASE IN BULK ?

NOSHOK PT40-750psig-2-2-10-36-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 750 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, G 1/4 B EN 837, integral cable 3 ft, integral orifice, Certified Calibration

PT40 Series High Accuracy Fixed Range Transmitters & Transducers

Download Literature
PT Series
NOSHOK 100, 200, 300 and 615 Series transmitters are replaced with the new PT Series, an enhanced and expanded portfolio of fixed range general purpose pressure transmitters that provides significant performance improvements and options.

Learn more →

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SERIES PT40
PRESSURE
RANGES
15psiv -15 psig to 0 psig 10psig 0 psig to 10 psig 750psig 0 psig to 750 psig 15000psig 0 psia to 15,000 psig
15psic -15 psig to 15 psig 15psig 0 psig to 15 psig 1000psig 0 psig to 1,000 psig 15psia 0 psia to 15 psia
30psic -15 psig to 30 psig 30psig 0 psig to 30 psig 1500psig 0 psig to 1,500 psig 30psia 0 psia to 30 psia
60psic -15 psig to 60 psig 60psig 0 psig to 60 psig 2000psig 0 psig to 2,000 psig 60psia 0 psia to 60 psia
100psic -15 psig to 100 psig 100psig 0 psig to 100 psig 3000psig 0 psig to 3,000 psig 100psia 0 psia to 100 psia
200psic -15 psig to 200 psig 150psig 0 psig to 150 psig 4000psig 0 psig to 4,000 psig 150psia 0 psia to 150 psia
300psic -15 psig to 300 psig 200psig 0 psig to 200 psig 5000psig 0 psig to 5,000 psig 200psia 0 psia to 200 psia
2psig 0 psig to 2 psig 300psig 0 psig to 300 psig 6000psig 0 psig to 6,000 psig 300psia 0 psia to 300 psia
3psig 0 psig to 3 psig 500psig 0 psig to 500 psig 7500psig 0 psig to 7,500 psig
5psig 0 psig to 5 psig 600psig 0 psig to 600 psig 10000psig 0 psig to 10,000 psig
psiv = vacuum gauge pressure   psic = compound gauge pressure   psig = gauge pressure
psia = absolute pressure   Other ranges available upon request
Note: Front flush connection is available for pressure ranges up to 0 psig to 8,000 psig
ACCURACIES 1 ±0.25% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
2 ±0.125% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 3 1 Vdc to 5 Vdc, 3-wire
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire
PROCESS
CONNECTIONS
1 1/8″ NPT male 9 SAE J1926-1:7/16-20 femalw 13 G 1 B Front flush (For ranges with span <30 psi)
1/4″ NPT male 10 G1/4B EN837 45  7/16-20 SAE J514 FIG 34B (Non-Adjustable)
8 1/2″ NPT male 11  G 1/2B Front flush (For ranges with span ≥30 psi) 83  G 1/2 B EN837
Other connections available upon request
ELECTRICAL
CONNECTIONS
2 4-pin Bayonet 17 DIN EN 175301-803 Form C w/ 3 ft. cable
3 6-pin Bayonet 25 M12 x 1 (4-pin)
7 DIN EN 175301-803 Form C 36 3 ft. Integral cable
16 1/2″ NPT conduit w/ 3 ft. cable 70 DIN EN 175301-803 Form C w/o mating connector
OPTION ST8 Threaded Orifice (0.8 mm)

Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

 

Description

NOSHOK PT40-750psig-2-2-10-36-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 750 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, G 1/4 B EN 837, integral cable 3 ft, integral orifice, Certified Calibration

PT40 Series High Accuracy Fixed Range Transmitters & Transducers

Download Literature
PT Series
NOSHOK 100, 200, 300 and 615 Series transmitters are replaced with the new PT Series, an enhanced and expanded portfolio of fixed range general purpose pressure transmitters that provides significant performance improvements and options.

Learn more →

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SERIES PT40
PRESSURE
RANGES
15psiv -15 psig to 0 psig 10psig 0 psig to 10 psig 750psig 0 psig to 750 psig 15000psig 0 psia to 15,000 psig
15psic -15 psig to 15 psig 15psig 0 psig to 15 psig 1000psig 0 psig to 1,000 psig 15psia 0 psia to 15 psia
30psic -15 psig to 30 psig 30psig 0 psig to 30 psig 1500psig 0 psig to 1,500 psig 30psia 0 psia to 30 psia
60psic -15 psig to 60 psig 60psig 0 psig to 60 psig 2000psig 0 psig to 2,000 psig 60psia 0 psia to 60 psia
100psic -15 psig to 100 psig 100psig 0 psig to 100 psig 3000psig 0 psig to 3,000 psig 100psia 0 psia to 100 psia
200psic -15 psig to 200 psig 150psig 0 psig to 150 psig 4000psig 0 psig to 4,000 psig 150psia 0 psia to 150 psia
300psic -15 psig to 300 psig 200psig 0 psig to 200 psig 5000psig 0 psig to 5,000 psig 200psia 0 psia to 200 psia
2psig 0 psig to 2 psig 300psig 0 psig to 300 psig 6000psig 0 psig to 6,000 psig 300psia 0 psia to 300 psia
3psig 0 psig to 3 psig 500psig 0 psig to 500 psig 7500psig 0 psig to 7,500 psig
5psig 0 psig to 5 psig 600psig 0 psig to 600 psig 10000psig 0 psig to 10,000 psig
psiv = vacuum gauge pressure   psic = compound gauge pressure   psig = gauge pressure
psia = absolute pressure   Other ranges available upon request
Note: Front flush connection is available for pressure ranges up to 0 psig to 8,000 psig
ACCURACIES 1 ±0.25% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
2 ±0.125% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 3 1 Vdc to 5 Vdc, 3-wire
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire
PROCESS
CONNECTIONS
1 1/8″ NPT male 9 SAE J1926-1:7/16-20 femalw 13 G 1 B Front flush (For ranges with span <30 psi)
1/4″ NPT male 10 G1/4B EN837 45  7/16-20 SAE J514 FIG 34B (Non-Adjustable)
8 1/2″ NPT male 11  G 1/2B Front flush (For ranges with span ≥30 psi) 83  G 1/2 B EN837
Other connections available upon request
ELECTRICAL
CONNECTIONS
2 4-pin Bayonet 17 DIN EN 175301-803 Form C w/ 3 ft. cable
3 6-pin Bayonet 25 M12 x 1 (4-pin)
7 DIN EN 175301-803 Form C 36 3 ft. Integral cable
16 1/2″ NPT conduit w/ 3 ft. cable 70 DIN EN 175301-803 Form C w/o mating connector
OPTION ST8 Threaded Orifice (0.8 mm)

Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.