NOSHOK 615-2-1-1-8-8 Pressure Transducer, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, Hirschmann

Part Number: 615-2-1-1-8-8
Online Prices

NOSHOK List price: Original price was: $619.57.Current price is: $495.66.

Warranty: 3 YR

NOSHOK 615-2-1-1-8-8 Pressure Transducer, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, Hirschmann

 

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire;
0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 1 Vdc to 5 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 145,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Adjustment ± 10% full scale for zero and span
Response time Less than 1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01%/ °F for zero and span
Media -20 °F to 212 °F (-30 °C to 100 °C)
Ambient -15 °F to 175 °F (-10 °C to 80 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire,
0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 15 g’s according to IEC 60068-2-6
Weight Approximately 7.2 oz.

 

Options & Accessories

 

M12 X 1 Optional Mating Connectors & Cab

   
   
   
   
   
   
   
   
   
   

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

 

3 Year Warranty

 

  • Vacuum ranges through 0 psig to 145,000 psig; absolute ranges from 0 psia to 15 psia
    through 0 psia to 300 psia
  • Current and voltage outputs available
  • 316 and 17-4PH stainless steel wetted parts
  • CE compliant to suppress RFI, EMI and ESD

 

Dimensions Tech Manuals Options Print Catalog Page 
 

 

ORDERING INFORMATION

SERIES 615 (internal diaphragm)   616 (front flush diaphragm)  
PRESSURE RANGES 30vac -30 inHg to 0 psig 15 0 psig to 15 psig 2000 0 psig to 2,000 psig 72000 0 psig to 72,000 psig
30/15 -30 inHg to 15 psig 30 0 psig to 30 psig 3000 0 psig to 3,000 psig 87000 0 psig to 87,000 psig
30/30 -30 inHg to 30 psig 60 0 psig to 60 psig 4000 0 psig to 4,000 psig 100000 0 psig to 100,000 psig
30/60 -30 inHg to 60 psig 100 0 psig to 100 psig 5000 0 psig to 5,000 psig 115000 0 psig to 115,000 psig
30/100 -30 inHg to 100 psig 150 0 psig to 150 psig 6000 0 psig to 6,000 psig 145000 0 psig to 145,000 psig
30/150 -30 inHg to 150 psig 200 0 psig to 200 psig 7500 0 psig to 7,500 psig 15A 0 psia to 15 psia
30/200 -30 inHg to 200 psig 300 0 psig to 300 psig 10000 0 psig to 10,000 psig 30A 0 psia to 30 psia
30/300 -30 inHg to 300 psig 500 0 psig to 500 psig 15000 0 psig to 15,000 psig 60A 0 psia to 60 psia
2 0 psig to 2 psig 600 0 psig to 600 psig 20000 0 psig to 20,000 psig 100A 0 psia to 100 psia
3 0 psig to 3 psig 750 0 psig to 750 psig 30000 0 psig to 30,000 psig 150A 0 psia to 150 psia
5 0 psig to 5 psig 1000 0 psig to 1,000 psig 36000 0 psig to 36,000 psig 200A 0 psia to 200 psia
10 0 psig to 10 psig 1500 0 psig to 1,500 psig 58000 0 psig to 58,000 psig 300A 0 psia to 300 psia
psig = gauge pressure          psia = absolute pressure          Other ranges available on special request
Note: Series 616 is available in pressure ranges up to 0 psig to 8,000 psig
ACCURACIES 1 ± 0.25 % full scale (BFSL)   2 ± 0.125 % full scale (BFSL  
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 4 1 Vdc to 6 Vdc, 3-wire**    
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire NOTE: 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc outputs are also available in
4-wire configurations for use with other electrical systems
3 1 Vdc to 5 Vdc, 3-wire 6 1 Vdc to 11 Vdc, 3-wire**
PROCESS
CONNECTIONS
615: 2  1/4″ NPT male 6 9/16″-18 UNF 2B high pressure cone*
(Standard on 30,000 to 120,000 psig)
8 1/2″ NPT male
616: 11 G 1/2 B
(Pressure ranges ≥ 0 psig to 30 psig)
13 G 1 B
(Pressure ranges < 0 psig to 30 psig)
Other connections available upon request.
ELECTRICAL
CONNECTIONS
1 36″ cable (connected to option 8) 8 Hirschmann (DIN EN 175301-803 Form A) 25 M12 x 1 (4-pin)
3 6-pin Bendix 14 Hirschmann type with 1/2″ NPT female conduit 36 Integral 36″ cable
6 1/2″ NPT conduit w/ 36″ cable            
OPTIONS ST8 SS Threaded Orifice G1 G 1 Weld-on adapter (616 only) G2 G 1/2 Weld-on adapter (616 only)
 * Equivalent to F250C Parker Autoclave
** Ranges up to 0 psig to 60,000 psig

 

 

Description

NOSHOK 615-2-1-1-8-8 Pressure Transducer, 0 psig to 2 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, Hirschmann

 

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire;
0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 1 Vdc to 5 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 145,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Adjustment ± 10% full scale for zero and span
Response time Less than 1 ms (between 10% and 90% full scale)
Service life >100,000,000 load cycles
Temperature ranges Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01%/ °F for zero and span
Media -20 °F to 212 °F (-30 °C to 100 °C)
Ambient -15 °F to 175 °F (-10 °C to 80 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire,
0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 15 g’s according to IEC 60068-2-6
Weight Approximately 7.2 oz.

 

Options & Accessories

 

M12 X 1 Optional Mating Connectors & Cab

   
   
   
   
   
   
   
   
   
   

615 & 616 Series High Accuracy Heavy-Duty Pressure Transducers

 

3 Year Warranty

 

  • Vacuum ranges through 0 psig to 145,000 psig; absolute ranges from 0 psia to 15 psia
    through 0 psia to 300 psia
  • Current and voltage outputs available
  • 316 and 17-4PH stainless steel wetted parts
  • CE compliant to suppress RFI, EMI and ESD

 

Dimensions Tech Manuals Options Print Catalog Page 
 

 

ORDERING INFORMATION

SERIES 615 (internal diaphragm)   616 (front flush diaphragm)  
PRESSURE RANGES 30vac -30 inHg to 0 psig 15 0 psig to 15 psig 2000 0 psig to 2,000 psig 72000 0 psig to 72,000 psig
30/15 -30 inHg to 15 psig 30 0 psig to 30 psig 3000 0 psig to 3,000 psig 87000 0 psig to 87,000 psig
30/30 -30 inHg to 30 psig 60 0 psig to 60 psig 4000 0 psig to 4,000 psig 100000 0 psig to 100,000 psig
30/60 -30 inHg to 60 psig 100 0 psig to 100 psig 5000 0 psig to 5,000 psig 115000 0 psig to 115,000 psig
30/100 -30 inHg to 100 psig 150 0 psig to 150 psig 6000 0 psig to 6,000 psig 145000 0 psig to 145,000 psig
30/150 -30 inHg to 150 psig 200 0 psig to 200 psig 7500 0 psig to 7,500 psig 15A 0 psia to 15 psia
30/200 -30 inHg to 200 psig 300 0 psig to 300 psig 10000 0 psig to 10,000 psig 30A 0 psia to 30 psia
30/300 -30 inHg to 300 psig 500 0 psig to 500 psig 15000 0 psig to 15,000 psig 60A 0 psia to 60 psia
2 0 psig to 2 psig 600 0 psig to 600 psig 20000 0 psig to 20,000 psig 100A 0 psia to 100 psia
3 0 psig to 3 psig 750 0 psig to 750 psig 30000 0 psig to 30,000 psig 150A 0 psia to 150 psia
5 0 psig to 5 psig 1000 0 psig to 1,000 psig 36000 0 psig to 36,000 psig 200A 0 psia to 200 psia
10 0 psig to 10 psig 1500 0 psig to 1,500 psig 58000 0 psig to 58,000 psig 300A 0 psia to 300 psia
psig = gauge pressure          psia = absolute pressure          Other ranges available on special request
Note: Series 616 is available in pressure ranges up to 0 psig to 8,000 psig
ACCURACIES 1 ± 0.25 % full scale (BFSL)   2 ± 0.125 % full scale (BFSL  
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 4 1 Vdc to 6 Vdc, 3-wire**    
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire NOTE: 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc outputs are also available in
4-wire configurations for use with other electrical systems
3 1 Vdc to 5 Vdc, 3-wire 6 1 Vdc to 11 Vdc, 3-wire**
PROCESS
CONNECTIONS
615: 2  1/4″ NPT male 6 9/16″-18 UNF 2B high pressure cone*
(Standard on 30,000 to 120,000 psig)
8 1/2″ NPT male
616: 11 G 1/2 B
(Pressure ranges ≥ 0 psig to 30 psig)
13 G 1 B
(Pressure ranges < 0 psig to 30 psig)
Other connections available upon request.
ELECTRICAL
CONNECTIONS
1 36″ cable (connected to option 8) 8 Hirschmann (DIN EN 175301-803 Form A) 25 M12 x 1 (4-pin)
3 6-pin Bendix 14 Hirschmann type with 1/2″ NPT female conduit 36 Integral 36″ cable
6 1/2″ NPT conduit w/ 36″ cable            
OPTIONS ST8 SS Threaded Orifice G1 G 1 Weld-on adapter (616 only) G2 G 1/2 Weld-on adapter (616 only)
 * Equivalent to F250C Parker Autoclave
** Ranges up to 0 psig to 60,000 psig