“Noshok 625-3000-1-1-2-36 Intrinsically Safe Pressure Transmitter” has been added to your cart. Continue shopping
Noshok 110-12-4-615-1-01-1-25 ASME-BPE Sanitary Clamp Pressure Transmitters
Part Number:
110-12-4-615-1-01-1-25
$1,266.87 Original price was: $1,266.87.$1,012.80Current price is: $1,012.80.
Noshok 110-12-4-615-1-01-1-25 ASME-BPE Sanitary Clamp Pressure Transmitter
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2
Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position.
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire |
| Pressure ranges | Vacuum through 0 psig to 400 psig |
| Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
| Stability | ±0.2% full scale for 1 year, non-accumulating |
| Adjustment | ±10% full scale for zero and span |
| Response time | < 10 ms |
| Service life | > 100,000,000 load cycles |
| Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) |
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) |
| Load limitations | ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 Ω for 1 Vdc to 5 Vdc output ≤ 10,000 Ω for 0 Vdc to 10 Vdc output ≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output |
| Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
| Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
| Measuring element | 316 stainless steel |
| Connection | 316 stainless steel |
| Housing material | 316 stainless steel |
| Environmental rating | IP65 |
| Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
| Electrical protection | Reverse polarity, overvoltage and short circuit protection |
| Shock | 1,000 g’s according to IEC 60068-2-27 |
| Vibration | 15 g’s according to IEC 60068-2-6 |
| Weight | Approximately 1.1 lb. |
Description
Noshok 110-12-4-615-1-01-1-25 ASME-BPE Sanitary Clamp Pressure Transmitter
NOSHOK pressure transmitters or transducers are not to be used in heat sterilization systems as stated in 3A Standard 74-03 paragraph D10.1.2
Diaphragm seal must be installed facing downward or in a vertical position for drainability. Do not install diaphragm seal facing in an upward position.
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire, 1 Vdc to 6 Vdc 3-wire, 0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc 3-wire |
| Pressure ranges | Vacuum through 0 psig to 400 psig |
| Accuracy | ±0.25% full scale (BFSL); Optional ±0.125% full scale (BFSL); (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
| Stability | ±0.2% full scale for 1 year, non-accumulating |
| Adjustment | ±10% full scale for zero and span |
| Response time | < 10 ms |
| Service life | > 100,000,000 load cycles |
| Temperature ranges | Compensated 32 °F to 175 °F (0 °C to 80 °C) Effect ±0.01%/°F for zero and span Media -40 °F to 300 °F (-40 °C to 150 °C) Ambient -40 °F to 176 °F (-40 °C to 80 °C) Storage -40 °F to 212 °F (-40 °C to 100 °C) |
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire, 1 Vdc to 6 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, Vdc to 11 Vdc, 3-wire) |
| Load limitations | ≤ (VPower -10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 Ω for 1 Vdc to 5 Vdc output ≤ 10,000 Ω for 0 Vdc to 10 Vdc output ≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output |
| Proof pressure | 3 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 1.75 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
| Burst pressure | 3.8 times full scale for 0 psig to 2 psig through 0 psig to 200 psig 4 times full scale for 0 psig to 300 psig through 0 psig to 400 psig |
| Measuring element | 316 stainless steel |
| Connection | 316 stainless steel |
| Housing material | 316 stainless steel |
| Environmental rating | IP65 |
| Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
| Electrical protection | Reverse polarity, overvoltage and short circuit protection |
| Shock | 1,000 g’s according to IEC 60068-2-27 |
| Vibration | 15 g’s according to IEC 60068-2-6 |
| Weight | Approximately 1.1 lb. |