Noshok 200-2000-1-5-2-7 Voltage Output Pressure replacement—PT40-2000psig-1-5-2-7

Part Number: 200-2000-1-5-2-7
Online Prices

NOSHOK List price: Original price was: $489.82.Current price is: $391.20.

11 in stock

aval to ship today
Warranty: 3 YR
PT40 AND THE PT30 REPLACES THE 100,200 AND THE 615 SERIES

PT40-2000psig-1-5-2-7

  • PT40 Series High Accuracy Fixed Range Pressure Transmitter
  • 0 to 2000 psi gauge
  • ±0.25% full scale non-linearity best fit straight line per IEC 61298-2 at reference conditions
  • 0 Vdc to 10 Vdc, 3-wire
  • 1/4 NPT male
  • DIN Form C
SPECIFICATIONS
Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL);
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale per year, non-accumulating
Adjustment ±10% full scale for zero and span
Response time ≤ 1 ms (between 10% and 90% full scale)
Pressure cycle limit ≤ 1 ms (between 10% and 90% full scale)
Service life > 100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ±0.017% full scale/ °F for zero and span
Media -22 °F to 212 °F (-30 °C to 100 °C)
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire,
1 Vdc to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥10,000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 3.5 oz.

Description

PT40-2000psig-1-5-2-7

  • PT40 Series High Accuracy Fixed Range Pressure Transmitter
  • 0 to 2000 psi gauge
  • ±0.25% full scale non-linearity best fit straight line per IEC 61298-2 at reference conditions
  • 0 Vdc to 10 Vdc, 3-wire
  • 1/4 NPT male
  • DIN Form C
SPECIFICATIONS
Output signals 0 Vdc to 5 Vdc, 3-wire; 0 Vdc to 10 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
1 Vdc to 6 Vdc, 3-wire; 1 Vdc to 11 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute from 0 psia to 15 psia through 0 psia to 300 psia
Accuracy ±0.5% full scale (BFSL); optional ±0.25% full scale (BFSL);
(Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.2% full scale per year, non-accumulating
Adjustment ±10% full scale for zero and span
Response time ≤ 1 ms (between 10% and 90% full scale)
Pressure cycle limit ≤ 1 ms (between 10% and 90% full scale)
Service life > 100,000,000 load cycles
Temperature ranges Compensated 32 °F to 176 °F (0 °C to 80 °C)
Effect ±0.017% full scale/ °F for zero and span
Media -22 °F to 212 °F (-30 °C to 100 °C)
Ambient -40 °F to 185 °F (-40 °C to 85 °C)
Storage -40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire, 1 Vdc to 5 Vdc, 3-wire,
1 Vdc to 6 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire, 1 Vdc to 11 Vdc, 3-wire)
Load limitations ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs;
≥10,000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs.
Current consumption 8 mA
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 316 stainless steel for vacuum through 300 psi;
17-4PH stainless steel for ≥500 psi
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 3.5 oz.