Noshok 611-50inH2O-1-1-W-62-50-CBC-LP-JB-HT Small diameter submersible pressure transducer

Part Number: 611-50inH2O-1-1-W-62-50-CBC-LP-JB-HT

Original price was: $2,200.00.Current price is: $1,800.00.

Available on backorder

LEAD TIME 3-4 weeks,,
Warranty: 3 YR
NEED TO PURCHASE IN BULK ?
Custom-Built NOSHOK Gauges Available!
We accept Visa, Mastercard, etc.

Hydrostatic level measurement for use in applications including bore holes and wells with small diameters (outer diameter 0.87″)Low power output signals for battery-powered applications, and optional temperature output available5:1 turndown using optional HART? signal.316 Stainless Steel, PVDF and polyurethane wetted parts CE compliant to suppress RFI, EMI and ESD

SERIES 611 611H 318 LN/Hastelloy C-276
PRESSURE
RANGES
50 inH2O 0 inH2O to 50 inH2O 5 0 psig to 5 psig (11.5 ftH2O) 50 0 psig to 50 psig (115 ftH2O)
100 inH2O 0 inH2O to 100 inH2O 10 0 psig to 10 psig (23.1 ftH2O) 100 0 psig to 100 psig (230.8 ftH2O)
150 inH2O 0 inH2O to 150 inH2O 15 0 psig to 15 psig (34.6 ftH2O) 25A 0 psiq to 25 psia
250 inH2O 0 inH2O to 250 inH2O 25 0 psig to 25 psig (57.7 ftH2O) 50A 0 psia to 50 psia
100A 0 psia to 100 psia
psig = gauge pressure    psia = absolute pressure    Other ranges and measuring units available on request
ACCURACIES 1 ± 1.0 of span 2 ± 0.5% of span
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 48 0.1 Vdc to 2.5 Vdc, 3 wire**
43 4 mA to 20 mA, 2-wire and HART® signal 49 0.1 Vdc to 2.5 Vdc x 2 (pressure and temperature) *, **
47 4 mA to 20 mA x 2 (pressure and temperature)*
PROCESS
CONNECTIONS
N Nosecone W Weighted nosecone
ELECTRICAL
CONNECTIONS
XX Standard polyurethane (PUR) cable 62-XX Polyurethane (PUR) cable with 1/2″ NPT conduit connection
38-XX Optional FEP cable 63-XX FEP cable with 1/2″ NPT conduit connection
NOTE: XX = length of cable in feet
OPTIONS CBC Cable Clamp LP Lightning Protection JB Cable Junction Box (NEMA 4X)
HT Increased media temperature (-40 °F to 176 °F)

* Temperature measurement is based on the media temperature range
** Low power is optimized for battery operation

Description

Hydrostatic level measurement for use in applications including bore holes and wells with small diameters (outer diameter 0.87″)Low power output signals for battery-powered applications, and optional temperature output available5:1 turndown using optional HART? signal.316 Stainless Steel, PVDF and polyurethane wetted parts CE compliant to suppress RFI, EMI and ESD

SERIES 611 611H 318 LN/Hastelloy C-276
PRESSURE
RANGES
50 inH2O 0 inH2O to 50 inH2O 5 0 psig to 5 psig (11.5 ftH2O) 50 0 psig to 50 psig (115 ftH2O)
100 inH2O 0 inH2O to 100 inH2O 10 0 psig to 10 psig (23.1 ftH2O) 100 0 psig to 100 psig (230.8 ftH2O)
150 inH2O 0 inH2O to 150 inH2O 15 0 psig to 15 psig (34.6 ftH2O) 25A 0 psiq to 25 psia
250 inH2O 0 inH2O to 250 inH2O 25 0 psig to 25 psig (57.7 ftH2O) 50A 0 psia to 50 psia
100A 0 psia to 100 psia
psig = gauge pressure    psia = absolute pressure    Other ranges and measuring units available on request
ACCURACIES 1 ± 1.0 of span 2 ± 0.5% of span
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 48 0.1 Vdc to 2.5 Vdc, 3 wire**
43 4 mA to 20 mA, 2-wire and HART® signal 49 0.1 Vdc to 2.5 Vdc x 2 (pressure and temperature) *, **
47 4 mA to 20 mA x 2 (pressure and temperature)*
PROCESS
CONNECTIONS
N Nosecone W Weighted nosecone
ELECTRICAL
CONNECTIONS
XX Standard polyurethane (PUR) cable 62-XX Polyurethane (PUR) cable with 1/2″ NPT conduit connection
38-XX Optional FEP cable 63-XX FEP cable with 1/2″ NPT conduit connection
NOTE: XX = length of cable in feet
OPTIONS CBC Cable Clamp LP Lightning Protection JB Cable Junction Box (NEMA 4X)
HT Increased media temperature (-40 °F to 176 °F)

* Temperature measurement is based on the media temperature range
** Low power is optimized for battery operation