A Premier Partner of NOSHOK inc. and Company EXCELLENCE in Measurement Solutions Dismiss
$664.37 Original price was: $664.37.$517.50Current price is: $517.50.
Noshok 621-15A-1-1-8-6 4-20 mA 1/2 NPT Conn 1/2 NPT Conduit Conn Explosion-Proof Transmitters-621/622 SERIES
Pressure Transmitter, 0 psia to 15 psia, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
| Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
| Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
| Stability | ≤±0.2% full scale for 1 year, non-accumulating |
| Response time | ≤1 ms (between 10% and 90% full scale) |
| Service life | >100,000,000 load cycles |
| Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
| Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
| Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
| Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
| Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
| Connection | 316 stainless steel |
| Housing material | 316 stainless steel |
| Environmental rating | IP67 |
| Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
| Electrical protection | Reverse polarity, over-voltage and short circuit protected |
| Shock | 1,000 g’s according to IEC 60068-2-27 |
| Vibration | 20 g’s according to IEC 60068-2-6 |
| Weight | Approximately 12 oz. |
Noshok 621-15A-1-1-8-6 4-20 mA 1/2 NPT Conn 1/2 NPT Conduit Conn Explosion-Proof Transmitters-621/622 SERIES
Pressure Transmitter, 0 psia to 15 psia, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/2 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
| Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
| Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
| Stability | ≤±0.2% full scale for 1 year, non-accumulating |
| Response time | ≤1 ms (between 10% and 90% full scale) |
| Service life | >100,000,000 load cycles |
| Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
| Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
| Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
| Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
| Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
| Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
| Connection | 316 stainless steel |
| Housing material | 316 stainless steel |
| Environmental rating | IP67 |
| Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
| Electrical protection | Reverse polarity, over-voltage and short circuit protected |
| Shock | 1,000 g’s according to IEC 60068-2-27 |
| Vibration | 20 g’s according to IEC 60068-2-6 |
| Weight | Approximately 12 oz. |
In stock
Date modified: Apr 15, 2023
In stock
Date modified: Apr 15, 2023
In stock
Date modified: Jun 20, 2025
No account yet?
Create an Account
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.