-29%
NOSHOK PT40-100psia-1-1-8-17-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi absolute, 0.25% of span, 4 mA to 20 mA, 2-wire, 1/2 NPT male, DIN form C with 3 ft cable, Certified Calibration
NOSHOK List price: $745.08 Original price was: $745.08.$595.00Current price is: $595.00.
NOSHOK 621-6000-1-1-2-6 4-20 mA 1/4 NPT Conn 1/2 NPT Conduit Conn Explosion-Proof Transmitter-6000 PSI
NOSHOK List price: $544.43 Original price was: $544.43.$416.00Current price is: $416.00.
NOSHOK 621-300-1-1-2-6 Details Pressure Transmitter, 0 psig to 300 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/4 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
Part Number:
621-300-1-1-2-6
Online Prices
NOSHOK List price: $562.20 Original price was: $562.20.$399.99Current price is: $399.99.
Pressure Transmitter, 0 psig to 300 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/4 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
Pressure Transmitter, 0 psig to 300 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/4 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
utput signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤±0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Service life | >100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP67 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 12 oz. |
Description
Pressure Transmitter, 0 psig to 300 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/4 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
Pressure Transmitter, 0 psig to 300 psig, 0.25% Accuracy (BFSL), 4 mA to 20 mA Output, 1/4 NPT Male, 1/2 NPT Conduit w/ 6 ft Cable Attached
utput signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤±0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Service life | >100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP67 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 12 oz. |