-28%Hot
NOSHOK 50-300-060-10/260-C-CC 5" Bimetal Thermometer, 1/2" NPT Bottom Conn, 6" Stem Length, 10/260 C, .250" Diameter, Certified Calibration
NOSHOK List price: $401.31 Original price was: $401.31.$199.95Current price is: $199.95.
NOSHOK 602-MFS-P2 1/4 NPT, Male x Female, 316 SS, Grafoil Packing, Hard Seat Block & Bleed Valve
NOSHOK List price: $305.29 Original price was: $305.29.$151.00Current price is: $151.00.
NOSHOK Explosion-Proof Pressure Transmitters-NOSHOK 621/622 Series -PICK YOUR CONFIGURATIONS Below
Part Number:
621/622 Series Explosion-Proof Pressure Transmitters
Online Prices
NOSHOK List price: $569.72 Original price was: $569.72.$410.00Current price is: $410.00.
Noshok 621/622 Series Explosion-Proof Pressure Transmitters
NOSHOK 621-100-1-1-2-37 Explosion-Proof Pressure Transmitter
621 | Stainless steel threaded connection | 622 | 316 Stainless steel flush diaphragm | 622H | Hastelloy C flush diaphragm | |||
PRESSURE RANGES |
30vac | -30 inHg to 0 psig | 5 | 0 psig to 5 psig | 300 | 0 psig to 300 psig | 6000 | 0 psig to 6,000 psig |
30/30 | -30 inHg to 30 psig | 10 | 0 psig to 10 psig | 500 | 0 psig to 500 psig | 8000 | 0 psig to 8,000 psig | |
30/60 | -30 inHg to 60 psig | 15 | 0 psig to 15 psig | 1000 | 0 psig to 1,000 psig | 10000 | 0 psig to 10,000 psig | |
30/100 | -30 inHg to 100 psig | 30 | 0 psig to 30 psig | 1500 | 0 psig to 1,500 psig | 15000 | 0 psig to 15,000 psig | |
30/160 | -30 inHg to 160 psig | 60 | 0 psig to 60 psig | 2000 | 0 psig to 2,000 psig | 15A | 0 psia to 15 psia | |
30/200 | -30 inHg to 200 psig | 100 | 0 psig to 100 psig | 3000 | 0 psig to 3,000 psig | 15A | 0 psia to 15 psia | |
30/300 | -30 inHg to 300 psig | 200 | 0 psig to 200 psig | 5000 | 0 psig to 5,000 psig | 100A | 0 psia to 100 psia | |
psig = gauge pressure psia = absolute pressure Other ranges available upon request | ||||||||
NOTE: 622 Series is available for pressure ranges up to 0 psig to 8,000 psig | ||||||||
ACCURACY | 1 | ± 0.25% full scale (BFSL) | ||||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 3 | 1 Vdc to 5 Vdc, 3-wire, low power | 31 | 0.5 Vdc to 4.5 Vdc, 3-wire , low power | ||
2 | 0 Vdc to 5 Vdc, 3-wire | 5 | 0 Vdc to 10 Vdc, 3-wire | |||||
PROCESS CONNECTIONS | 2 | 1/4″ NPT male | 11 | G1/2B* | ||||
8 | 1/2″ NPT male | 13 | G1B (622 Series only, <30 psig) | |||||
ELECTRICAL CONNECTIONS | 6 | 1/2″ NPT male conduit with 6′ integral cable | 37 | 1/2″ NPT male conduit with 6′ flying leads with epoxy seal | ||||
OPTIONS | ST8 | Threaded Orifice (621 Series only) |
20 | 20′ Cable/lead (attached to electrical connection 6 or 37) |
30 | 30′ Cable/lead (attached to electrical connection 6 or 37) |
Download Literature
Oil & Gas
Water/
Wastewater
Wastewater
- Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0
- Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 100 psia
- Current and voltage outputs available
- 316 stainless Steel and Elgiloy wetted parts
- Factory Mutual and Canadian Standards Association approved
- CE compliant to suppress RFI, EMI and ESD
- NACE MR0175/ISO 15156 compliant
- NSI/ISA-12.27.01 approved single seal
NOSHOK 621 and 622 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
- Explosion-proof with entity approved for: Class I, Division 1, Groups A, B, C and D.
- Dust Ignition-proof with entity approval for class II/III, Division 1, Groups E, F and G.
- Maximum electrical ratings 30V, 20 mA.
- CE compliant with pressure equipment directive 2014/68/EU.
- ANSI/ISA-12.27.01, Approved single seal.
- Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining and well head measurement
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤±0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Service life | >100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP67 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 12 oz. |
|
4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire | |
Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤±0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Service life | >100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire) 5 Vdc to 30 Vdc (0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP67 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 12 oz. |
Description
Noshok 621/622 Series Explosion-Proof Pressure Transmitters
NOSHOK 621-100-1-1-2-37 Explosion-Proof Pressure Transmitter
621 | Stainless steel threaded connection | 622 | 316 Stainless steel flush diaphragm | 622H | Hastelloy C flush diaphragm | |||
PRESSURE RANGES |
30vac | -30 inHg to 0 psig | 5 | 0 psig to 5 psig | 300 | 0 psig to 300 psig | 6000 | 0 psig to 6,000 psig |
30/30 | -30 inHg to 30 psig | 10 | 0 psig to 10 psig | 500 | 0 psig to 500 psig | 8000 | 0 psig to 8,000 psig | |
30/60 | -30 inHg to 60 psig | 15 | 0 psig to 15 psig | 1000 | 0 psig to 1,000 psig | 10000 | 0 psig to 10,000 psig | |
30/100 | -30 inHg to 100 psig | 30 | 0 psig to 30 psig | 1500 | 0 psig to 1,500 psig | 15000 | 0 psig to 15,000 psig | |
30/160 | -30 inHg to 160 psig | 60 | 0 psig to 60 psig | 2000 | 0 psig to 2,000 psig | 15A | 0 psia to 15 psia | |
30/200 | -30 inHg to 200 psig | 100 | 0 psig to 100 psig | 3000 | 0 psig to 3,000 psig | 15A | 0 psia to 15 psia | |
30/300 | -30 inHg to 300 psig | 200 | 0 psig to 200 psig | 5000 | 0 psig to 5,000 psig | 100A | 0 psia to 100 psia | |
psig = gauge pressure psia = absolute pressure Other ranges available upon request | ||||||||
NOTE: 622 Series is available for pressure ranges up to 0 psig to 8,000 psig | ||||||||
ACCURACY | 1 | ± 0.25% full scale (BFSL) | ||||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 3 | 1 Vdc to 5 Vdc, 3-wire, low power | 31 | 0.5 Vdc to 4.5 Vdc, 3-wire , low power | ||
2 | 0 Vdc to 5 Vdc, 3-wire | 5 | 0 Vdc to 10 Vdc, 3-wire | |||||
PROCESS CONNECTIONS | 2 | 1/4″ NPT male | 11 | G1/2B* | ||||
8 | 1/2″ NPT male | 13 | G1B (622 Series only, <30 psig) | |||||
ELECTRICAL CONNECTIONS | 6 | 1/2″ NPT male conduit with 6′ integral cable | 37 | 1/2″ NPT male conduit with 6′ flying leads with epoxy seal | ||||
OPTIONS | ST8 | Threaded Orifice (621 Series only) |
20 | 20′ Cable/lead (attached to electrical connection 6 or 37) |
30 | 30′ Cable/lead (attached to electrical connection 6 or 37) |
Download Literature
Oil & Gas
Water/
Wastewater
Wastewater
- Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0
- Vacuum and compound ranges through 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 100 psia
- Current and voltage outputs available
- 316 stainless Steel and Elgiloy wetted parts
- Factory Mutual and Canadian Standards Association approved
- CE compliant to suppress RFI, EMI and ESD
- NACE MR0175/ISO 15156 compliant
- NSI/ISA-12.27.01 approved single seal
NOSHOK 621 and 622 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
- Explosion-proof with entity approved for: Class I, Division 1, Groups A, B, C and D.
- Dust Ignition-proof with entity approval for class II/III, Division 1, Groups E, F and G.
- Maximum electrical ratings 30V, 20 mA.
- CE compliant with pressure equipment directive 2014/68/EU.
- ANSI/ISA-12.27.01, Approved single seal.
- Ideal for applications including chemical processing, gas pressure measurement, oil field & offshore, mining and well head measurement
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 3-wire; 0.5 Vdc to 4.5 Vdc, 3-wire |
Pressure ranges | Vacuum through 0 psi to 15,000 psi Absolute from 0 psia to 15 psia through 0 psia to 100 psia |
Accuracy | ±0.25% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤±0.2% full scale for 1 year, non-accumulating |
Response time | ≤1 ms (between 10% and 90% full scale) |
Service life | >100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.011% full scale/ °F Span effect ±0.011% full scale/ °F Media T6: -40 °F to 131 °F (-40 °C to 55 °C) T5: -40 °F to 158 °F (-40 °C to 70 °C) T4: -40 °F to 212 °F (-40 °C to 100 °C) Ambient T6: -40 °F to 140 °F (-40 °C to 60 °C) T5: -40 °F to 167 °F (-40 °C to 75 °C) T4: -40 °F to 221 °F (-40 °C to 105 °C) Storage -40 °F to 221 °F (-40 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 1 Vdc to 5 Vdc, 3-wire |
Proof pressure | 3 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 3.8 times full scale for ranges 0 psi to 15 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 621 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with Elgiloy ranges 0 psig to 500 psig and higher; 622 Series is 316 stainless steel with NBR o-ring; (FKM o-ring optional) |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP67 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 12 oz. |
|