Noshok 625-5-1-1-8-25 Intrinsically Safe Pressure Transmitter
Part Number:
625-5-1-1-8-25
Online Prices
NOSHOK List price: $725.18 Original price was: $725.18.$580.00Current price is: $580.00.
Noshok 625-5-1-1-8-25 Intrinsically Safe Pressure Transmitter
Low pressure ranges for vapor recovery applications,?vacuum and compound ranges through 0 psig to 15,000 psig;?absolute ranges from 0 psia to 15 psia through 0 psia to 300 psia,The NOSHOK Series 625 and 626 pressure transmitters combine the reliability and long life of diffused semiconductor and sputtered thin film strain gauge sensors with safe electronics for outstanding performance and value. These transmitters were designed for applications that require pressure measurement in hazardous environments. All wetted parts are made of stainless steel (Hastelloy C4 optional on front flush model), welded with no internal O-rings, gaskets or seals. The 625 transmitter includes an internal diaphragm while the 626 transmitter utilizes a front flush diaphragm.
RIES | 625 | Stainless steel threaded connection | 626 | 316 Stainless steel flush diaphragm | 626H | Hastelloy flush diaphragm | ||||
PRESSURE RANGES |
4/12 oz/in2 | -4 oz/in2 to 12 oz/in2 | 30/100 | -30 inHg to 100 psig | 150 | 0 psig to 150 psig | 5000 | 0 psig to 5,000 psig | 15A | 0 psia to 15 psia |
12 oz/in2 | 0 oz/in2 to 12 oz/in2 | 30/150 | -30 inHg to 150 psig | 200 | 0 psig to 200 psig | 6000 | 0 psig to 6,000 psig | 30A | 0 psia to 30 psia | |
16 oz/in2 | 0 oz/in2 to 16 oz/in2 | 30/200 | -30 inHg to 200 psig | 300 | 0 psig to 300 psig | 7500 | 0 psig to 7,500 psig | 60A | 0 psia to 60 psia | |
50 inH2O | 0 inH2O to 50 inH2O | 3 | 0 psig to 3 psig | 500 | 0 psig to 500 psig | 8000 | 0 psig to 8,000 psig | 100A | 0 psia to 100 psia | |
100 inH2O | 0 inH2O to 100 inH2O | 5 | 0 psig to 5 psig | 750 | 0 psig to 750 psig | 10000 | 0 psig to 10,000 psig | 150A | 0 psia to 150 psia | |
30vac | -30 inHg to 0 psig | 15 | 0 psig to 15 psig | 1000 | 0 psig to 1,000 psig | 15000 | 0 psig to 15,000 psig | 200A | 0 psia to 200 psia | |
30/15 | -30 inHg to 15 psig | 30 | 0 psig to 30 psig | 1500 | 0 psig to 1,500 psig | 250A | 0 psia to 250 psia | |||
30/30 | -30 inHg to 30 psig | 60 | 0 psig to 60 psig | 2000 | 0 psig to 2,000 psig | |||||
30/60 | -30 inHg to 60 psig | 100 | 0 psig to 100 psig | 3000 | 0 psig to 3,000 psig | |||||
psig = gauge pressure | psia = absolute pressure | Other ranges available upon request | ||||||||
NOTE: Series 626 is available for pressure ranges up to 0 psig to 8,000 psig | ||||||||||
ACCURACY | 1 | ± 0.25% full scale (BFSL) | 2 | ± 0.125% full scale (BFSL) | ||||||
OUTPUT SIGNAL | 1 | 4 mA to 20 mA, 2-wire | ||||||||
PROCESS CONNECTIONS | 2 | 1/4″ NPT male | 13 | G1B (626 Series only, <30 psig) | ||||||
8 | 1/2″ NPT male | 45 | 7/16-20 SAE J514 FIG 34B (Non-Adjustable) | |||||||
11 | G1/2B* | |||||||||
ELECTRICAL CONNECTIONS | 1 | DIN EN 175301-803 Form A w/ 36” Cable | 14 | DIN EN 175301-803 Form A with 1/2″ NPT female conduit – IP65 | ||||||
3 | 6-pin Bayonet -IP65 | 25 | M12x1 (4-pin) IP67 | |||||||
8 | DIN EN 175301-803 Form A | 36 | Integral Cable 36″ – IP67 | |||||||
OPTION | ST8 | Threaded Orifice (625 Series only) |
* 626 Series only, G 1/2 B Flush (≥ 30 psig).
SPECIFICATIONS | |
Output signal | 4 mA to 20 mA, 2-wire |
Pressure ranges | Vacuum through 0 psig to 15,000 psig Absolute from 0 psia to 15 psia through 0 psia to 300 psia |
Accuracy | ±0.25% full scale (BFSL); optional ±0.125% full scale (BFSL) (Includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤ ±0.2% full scale for 1 year, non-accumulating |
Adjustment | ± 10% full scale for zero and span |
Response time | ≤ 1 ms (between 10% and 90% full scale) |
Service life | > 100,000,000 load cycles |
Temperature ranges | Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect is ±0.011% full scale/ °F Span effect is ±0.011% full scale/ °F Media -4 °F to 185 °F (-20 °C to 85 °C) Ambient -4 °F to 176 °F (-20 °C to 80 °C) Storage -22 °F to 221 °F (-30 °C to 105 °C) |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp |
Proof pressure | 3.5 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi 2 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 1.5 times full scale for 0 psi to 15,000 psi |
Burst pressure | 4 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi 4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi 3 times full scale for 0 psi to 15,000 psi |
Measuring element | 625 Series is 316 stainless steel for ranges up through 0 psi to 300 psi, 316 stainless steel with 17-4PH stainless steel for ≥300 psi; 626 Series is 316 stainless steel with NBR o-ring |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP65 to IP67 depending upon electrical connection |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protected |
Shock | 1,000 g’s according to IEC 60068-2-27 |
Vibration | 20 g’s according to IEC 60068-2-6 |
Weight | Approximately 7 oz. |
Description
Noshok 625-5-1-1-8-25 Intrinsically Safe Pressure Transmitter
Low pressure ranges for vapor recovery applications,?vacuum and compound ranges through 0 psig to 15,000 psig;?absolute ranges from 0 psia to 15 psia through 0 psia to 300 psia,The NOSHOK Series 625 and 626 pressure transmitters combine the reliability and long life of diffused semiconductor and sputtered thin film strain gauge sensors with safe electronics for outstanding performance and value. These transmitters were designed for applications that require pressure measurement in hazardous environments. All wetted parts are made of stainless steel (Hastelloy C4 optional on front flush model), welded with no internal O-rings, gaskets or seals. The 625 transmitter includes an internal diaphragm while the 626 transmitter utilizes a front flush diaphragm.
RIES | 625 | Stainless steel threaded connection | 626 | 316 Stainless steel flush diaphragm | 626H | Hastelloy flush diaphragm | ||||
PRESSURE RANGES |
4/12 oz/in2 | -4 oz/in2 to 12 oz/in2 | 30/100 | -30 inHg to 100 psig | 150 | 0 psig to 150 psig | 5000 | 0 psig to 5,000 psig | 15A | 0 psia to 15 psia |
12 oz/in2 | 0 oz/in2 to 12 oz/in2 | 30/150 | -30 inHg to 150 psig | 200 | 0 psig to 200 psig | 6000 | 0 psig to 6,000 psig | 30A | 0 psia to 30 psia | |
16 oz/in2 | 0 oz/in2 to 16 oz/in2 | 30/200 | -30 inHg to 200 psig | 300 | 0 psig to 300 psig | 7500 | 0 psig to 7,500 psig | 60A | 0 psia to 60 psia | |
50 inH2O | 0 inH2O to 50 inH2O | 3 | 0 psig to 3 psig | 500 | 0 psig to 500 psig | 8000 | 0 psig to 8,000 psig | 100A | 0 psia to 100 psia | |
100 inH2O | 0 inH2O to 100 inH2O | 5 | 0 psig to 5 psig | 750 | 0 psig to 750 psig | 10000 | 0 psig to 10,000 psig | 150A | 0 psia to 150 psia | |
30vac | -30 inHg to 0 psig | 15 | 0 psig to 15 psig | 1000 | 0 psig to 1,000 psig | 15000 | 0 psig to 15,000 psig | 200A | 0 psia to 200 psia | |
30/15 | -30 inHg to 15 psig | 30 | 0 psig to 30 psig | 1500 | 0 psig to 1,500 psig | 250A | 0 psia to 250 psia | |||
30/30 | -30 inHg to 30 psig | 60 | 0 psig to 60 psig | 2000 | 0 psig to 2,000 psig | |||||
30/60 | -30 inHg to 60 psig | 100 | 0 psig to 100 psig | 3000 | 0 psig to 3,000 psig | |||||
psig = gauge pressure | psia = absolute pressure | Other ranges available upon request | ||||||||
NOTE: Series 626 is available for pressure ranges up to 0 psig to 8,000 psig | ||||||||||
ACCURACY | 1 | ± 0.25% full scale (BFSL) | 2 | ± 0.125% full scale (BFSL) | ||||||
OUTPUT SIGNAL | 1 | 4 mA to 20 mA, 2-wire | ||||||||
PROCESS CONNECTIONS | 2 | 1/4″ NPT male | 13 | G1B (626 Series only, <30 psig) | ||||||
8 | 1/2″ NPT male | 45 | 7/16-20 SAE J514 FIG 34B (Non-Adjustable) | |||||||
11 | G1/2B* | |||||||||
ELECTRICAL CONNECTIONS | 1 | DIN EN 175301-803 Form A w/ 36” Cable | 14 | DIN EN 175301-803 Form A with 1/2″ NPT female conduit – IP65 | ||||||
3 | 6-pin Bayonet -IP65 | 25 | M12x1 (4-pin) IP67 | |||||||
8 | DIN EN 175301-803 Form A | 36 | Integral Cable 36″ – IP67 | |||||||
OPTION | ST8 | Threaded Orifice (625 Series only) |
* 626 Series only, G 1/2 B Flush (≥ 30 psig).