NOSHOK PT30-10000psig-1-2-8-25 High Performance Fixed Range Pressure Transmitter, 0 to 10000 psi, 0.25% of span,0 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin

Part Number: PT30-10000psig-1-2-8-25

Original price was: $304.68.Current price is: $243.50.

Available on backorder

LEAD TIME 7-8 WEEKS-NON STOCK ITEM
Warranty: 3 YEARS
PT40 AND 30 SERIES is REPLACING THE 100,200 AND 615 SERIES
Custom-Built NOSHOK Gauges Available!
We accept Visa, Mastercard, etc.

NOSHOK PT30-10000psig-1-2-8-25 High Performance Fixed Range Pressure Transmitter, 0 to 10000 psi gauge, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
0 Vdc to 10 Vdc, 3-wire; 0.5 to 4.5 Vdc, 3-wire; 0.5 to 4.5 Vdc ratiometric, 3-wire
Pressure ranges Gauge, compound, absolute and vacuum ranges from 2 psi to 15,000 psi
Accuracy* ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions
Response time <1 ms
Service life >10 million load cycles
Temperature ranges* Compensated:
Media:
Ambient:
Storage:
-4 °F to 185 °F (-20 °C to 85 °C)
-22 °F to 221 °F (-30 °C to 105 °C)
-4 °F to 185 °F (-20 °C to 85 °C)
-40 °F to 257 °F (-40 °C to 125 °C)
Power requirement* 12 Vdc to 36 Vdc:

4.5 Vdc to 5.5 Vdc:

4 mA to 20 mA, 2-wire
0 Vdc to 5 Vdc, 3-wire
1 Vdc to 5 Vdc, 3-wire
0 Vdc to 10 Vdc, 3-wire
0.5 Vdc to 4.5 Vdc non-ratiometric, 3-wire
0.5 Vdc to 4.5 Vdc ratiometric, 3-wire
Proof pressure <7,500 psi:
7,500 – 10,000 psi:
>10,000 psi:
2 times full scale
1.5 times full scale
1.2 times full scale
Burst pressure <7,500 psi:
7,500 – 10,000 psi:
>10,000 psi:
3 times full scale
2 times full scale
1.5 times full scale
Measuring element 316 Stainless Steel
Process connection 316 Stainless Steel
Electical connection Stainless Steel and Glass Filled PA
Housing material 304 Stainless Steel
Environmental rating IP65: DIN EN 175301-803 Form A, DIN EN 175301-803 Form C
IP67: 4-pin Bayonet, 6-pin Bayonet, Packard, M12 x 1 (4-pin), Deutsch
IP68: Integral cable (gauge reference devices < 400 psi are IP67)
Electromagnetic rating Immunity per IEC 61000-6-2
Radiation per IEC 61000-6-3
Electrical protection Reverse polarity and short circuit protection
Shock 200 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 4.5 oz.

Description

NOSHOK PT30-10000psig-1-2-8-25 High Performance Fixed Range Pressure Transmitter, 0 to 10000 psi gauge, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc, 3-wire; 1 Vdc to 5 Vdc, 3-wire;
0 Vdc to 10 Vdc, 3-wire; 0.5 to 4.5 Vdc, 3-wire; 0.5 to 4.5 Vdc ratiometric, 3-wire
Pressure ranges Gauge, compound, absolute and vacuum ranges from 2 psi to 15,000 psi
Accuracy* ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions
Response time <1 ms
Service life >10 million load cycles
Temperature ranges* Compensated:
Media:
Ambient:
Storage:
-4 °F to 185 °F (-20 °C to 85 °C)
-22 °F to 221 °F (-30 °C to 105 °C)
-4 °F to 185 °F (-20 °C to 85 °C)
-40 °F to 257 °F (-40 °C to 125 °C)
Power requirement* 12 Vdc to 36 Vdc:

4.5 Vdc to 5.5 Vdc:

4 mA to 20 mA, 2-wire
0 Vdc to 5 Vdc, 3-wire
1 Vdc to 5 Vdc, 3-wire
0 Vdc to 10 Vdc, 3-wire
0.5 Vdc to 4.5 Vdc non-ratiometric, 3-wire
0.5 Vdc to 4.5 Vdc ratiometric, 3-wire
Proof pressure <7,500 psi:
7,500 – 10,000 psi:
>10,000 psi:
2 times full scale
1.5 times full scale
1.2 times full scale
Burst pressure <7,500 psi:
7,500 – 10,000 psi:
>10,000 psi:
3 times full scale
2 times full scale
1.5 times full scale
Measuring element 316 Stainless Steel
Process connection 316 Stainless Steel
Electical connection Stainless Steel and Glass Filled PA
Housing material 304 Stainless Steel
Environmental rating IP65: DIN EN 175301-803 Form A, DIN EN 175301-803 Form C
IP67: 4-pin Bayonet, 6-pin Bayonet, Packard, M12 x 1 (4-pin), Deutsch
IP68: Integral cable (gauge reference devices < 400 psi are IP67)
Electromagnetic rating Immunity per IEC 61000-6-2
Radiation per IEC 61000-6-3
Electrical protection Reverse polarity and short circuit protection
Shock 200 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 4.5 oz.