Product SKU Price Quantity Subtotal
× NOSHOK PT40-600psig-2-3-8-70-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C no mate, Certified Calibration NOSHOK PT40-600psig-2-3-8-70-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C no mate, Certified Calibration PT40-600psig-2-3-8-70-CC $526.84
$526.84
× NOSHOK PT40-600psig-2-3-8-3-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-8-3-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, integral orifice, Certified Calibration PT40-600psig-2-3-8-3-ST8-CC $566.58
$566.58
× NOSHOK PT40-600psig-2-3-8-36-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, Certified Calibration NOSHOK PT40-600psig-2-3-8-36-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, Certified Calibration PT40-600psig-2-3-8-36-CC $543.38
$543.38
× NOSHOK PT40-600psig-2-3-8-25-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, Certified Calibration NOSHOK PT40-600psig-2-3-8-25-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, Certified Calibration PT40-600psig-2-3-8-25-CC $539.86
$539.86
× NOSHOK PT40-600psig-2-3-8-36-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-8-36-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, integral orifice, Certified Calibration PT40-600psig-2-3-8-36-ST8-CC $555.14
$555.14
× NOSHOK PT40-600psig-2-3-8-3-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, integral orifice NOSHOK PT40-600psig-2-3-8-3-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, integral orifice PT40-600psig-2-3-8-3-ST8 $476.74
$476.74
× NOSHOK PT40-600psig-2-3-8-3-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, Certified Calibration NOSHOK PT40-600psig-2-3-8-3-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 6 pin, Certified Calibration PT40-600psig-2-3-8-3-CC $554.82
$554.82
× NOSHOK PT40-600psig-2-3-8-2-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-8-2-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin, integral orifice, Certified Calibration PT40-600psig-2-3-8-2-ST8-CC $564.63
$564.63
× NOSHOK PT40-600psig-2-3-8-70-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C no mate, integral orifice NOSHOK PT40-600psig-2-3-8-70-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C no mate, integral orifice PT40-600psig-2-3-8-70-ST8 $448.76
$448.76
× NOSHOK PT40-600psig-2-3-8-7 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C NOSHOK PT40-600psig-2-3-8-7 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C PT40-600psig-2-3-8-7 $437.00
$437.00
× NOSHOK PT40-600psig-2-3-8-36-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, integral orifice NOSHOK PT40-600psig-2-3-8-36-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, integral cable 3 ft, integral orifice PT40-600psig-2-3-8-36-ST8 $465.30
$465.30
× NOSHOK PT40-600psig-2-3-83-16-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, 1/2 NPT conduit with 3 ft cable, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-83-16-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, 1/2 NPT conduit with 3 ft cable, integral orifice, Certified Calibration PT40-600psig-2-3-83-16-ST8-CC $553.16
$553.16
× NOSHOK PT40-600psig-2-3-8-2-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin, Certified Calibration NOSHOK PT40-600psig-2-3-8-2-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin, Certified Calibration PT40-600psig-2-3-8-2-CC $552.87
$552.87
× NOSHOK PT40-600psig-2-3-8-25-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, integral orifice NOSHOK PT40-600psig-2-3-8-25-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, integral orifice PT40-600psig-2-3-8-25-ST8 $461.78
$461.78
× NOSHOK PT40-600psig-2-3-8-17-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C with 3 ft cable, integral orifice NOSHOK PT40-600psig-2-3-8-17-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C with 3 ft cable, integral orifice PT40-600psig-2-3-8-17-ST8 $459.68
$459.68
× NOSHOK PT40-600psig-2-3-8-2 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin NOSHOK PT40-600psig-2-3-8-2 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, bayonet 4 pin PT40-600psig-2-3-8-2 $463.03
$463.03
× NOSHOK PT40-600psig-2-3-83-17-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, DIN form C with 3 ft cable, integral orifice NOSHOK PT40-600psig-2-3-83-17-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, DIN form C with 3 ft cable, integral orifice PT40-600psig-2-3-83-17-ST8 $459.68
$459.68
× NOSHOK PT40-600psig-2-3-8-7-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C, Certified Calibration NOSHOK PT40-600psig-2-3-8-7-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C, Certified Calibration PT40-600psig-2-3-8-7-CC $526.84
$526.84
× NOSHOK PT40-600psig-2-3-8-25-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-8-25-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin, integral orifice, Certified Calibration PT40-600psig-2-3-8-25-ST8-CC $551.62
$551.62
× NOSHOK PT40-600psig-2-3-8-25 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin NOSHOK PT40-600psig-2-3-8-25 High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, M12 x 1 4 pin PT40-600psig-2-3-8-25 $450.02
$450.02
× NOSHOK PT40-600psig-2-3-8-17-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C with 3 ft cable, Certified Calibration NOSHOK PT40-600psig-2-3-8-17-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C with 3 ft cable, Certified Calibration PT40-600psig-2-3-8-17-CC $537.76
$537.76
× NOSHOK PT40-600psig-2-3-8-7-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C, integral orifice, Certified Calibration NOSHOK PT40-600psig-2-3-8-7-ST8-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 600 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/2 NPT male, DIN form C, integral orifice, Certified Calibration PT40-600psig-2-3-8-7-ST8-CC $538.60
$538.60

Cart Totals

Cart totals

Subtotal $11,234.09
Shipping
Total $11,234.09