Noshok 40-412-60000-PSI-/BAR-9/16-HPM-O2 9/16-18 UNF 2A left hand male thread Dry, lower back connection Extreme High Pressure Gauge
SKU:
40-412-60000-PSI-/BAR-9/16-HPM-O2
$ 2,825.28
Noshok 40-412-60000-PSI-/BAR-9/16-HPM-O2 9/16-18 UNF 2A left hand male thread Dry, lower back connection Extreme High Pressure Gauge quantity
$ 2,825.28
×
Noshok 110-16-4-615-61-1-8 Sanitary Transducer 2 Tri-Clamp Conn 0 psig To 300 psig
SKU:
110-16-4-615-61-1-8
$ 697.58
Noshok 110-16-4-615-61-1-8 Sanitary Transducer 2 Tri-Clamp Conn 0 psig To 300 psig quantity
$ 697.58
×
NOSHOK PT20-100psia-1-5-83-7-ST8 General Purpose Fixed Range Pressure Transmitter, 0 to 100 psi absolute, ?0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, G 1/2 B EN 837, DIN form C, integral orifice
SKU:
PT20-100psia-1-5-83-7-ST8
$ 180.26
NOSHOK PT20-100psia-1-5-83-7-ST8 General Purpose Fixed Range Pressure Transmitter, 0 to 100 psi absolute, ?0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, G 1/2 B EN 837, DIN form C, integral orifice quantity
$ 180.26
×
NOSHOK PT40-150psia-2-2-2-3-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 150 psi absolute, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 1/4 NPT male, bayonet 6 pin, integral orifice
SKU:
PT40-150psia-2-2-2-3-ST8
$ 580.51
NOSHOK PT40-150psia-2-2-2-3-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 150 psi absolute, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 1/4 NPT male, bayonet 6 pin, integral orifice quantity
$ 580.51
×
NOSHOK PT40-5psig-2-2-83-16-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, 1/2 NPT conduit with 3 ft cable, integral orifice
SKU:
PT40-5psig-2-2-83-16-ST8
$ 463.32
NOSHOK PT40-5psig-2-2-83-16-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, ?0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, G 1/2 B EN 837, 1/2 NPT conduit with 3 ft cable, integral orifice quantity
$ 463.32
×
NOSHOK PT40-5psig-1-3-13-36-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1 B front flush , integral cable 3 ft, Certified Calibration
SKU:
PT40-5psig-1-3-13-36-CC
$ 545.89
NOSHOK PT40-5psig-1-3-13-36-CC High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, G 1 B front flush , integral cable 3 ft, Certified Calibration quantity
$ 545.89
×
NOSHOK PT40-15psia-1-5-45-70-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 15 psi absolute, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 7/16-20 male SAE J514 FIG 34B (non-adjustable), DIN form C no mate, integral orifice
SKU:
PT40-15psia-1-5-45-70-ST8
$ 507.06
NOSHOK PT40-15psia-1-5-45-70-ST8 High Accuracy Fixed Range Pressure Transmitter, 0 to 15 psi absolute, ?0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 7/16-20 male SAE J514 FIG 34B (non-adjustable), DIN form C no mate, integral orifice quantity
$ 507.06
×
Noshok 100-12-1-40-64-2-2 4 Sanitary Gauge, 0 to 400 psi, 1-1/2 Clamp, Silicone Fill, Adjustable Pointer
SKU:
100-12-1-40-64-2-2
$ 475.20
Noshok 100-12-1-40-64-2-2 4 Sanitary Gauge, 0 to 400 psi, 1-1/2 Clamp, Silicone Fill, Adjustable Pointer quantity
$ 475.20