Noshok 623/624 Series Non-Incendive Transmitters
Noshok 623/624 Series Non-Incendive Transmitters List Price Original price was: $606.62.Current price is: $470.50.
Back to products
NOSHOK PT41-100000psig-1-1-6-14 High Pressure Transmitter, 0 to 100000 psi
NOSHOK PT41-100000psig-1-1-6-14 High Pressure Transmitter, 0 to 100000 psi List Price Original price was: $4,465.26.Current price is: $3,572.22.

Noshok 304-16-290/1450-1-1-71-30P-TC Sanitary Transmitter

Part Number: 304-16-290/1450-1-1-71-30P-TC

List Price Original price was: $2,072.60.Current price is: $1,758.20.

1 in stock (can be backordered)

In Stock And Avalable For immediate Delivery
PRICES ARE NOT ALWAYS FINAL-CALL US
PRICES NOW REFLECT IEEPA/Other Tariff Surcharges-

30 Series Sanitary Transmitter, Tri Clamp 2

30 Series Sanitary Transmitter, Tri Clamp 2”, Intelligent from 0 psig to 290 to 0 psi to 1450 psig, 0.1% of adjusted span, 4-20 mA/2-wire, PG9 Cable Gland, 30′ Polyurethane Cable, Transparent Cover

deal for applications including tank level measurement, food & beverage, dairy, breweries, chemical processing and pharmaceutical.

  • 300 Series: ranges from 40 inH2O to 60 psig 
    301 Series: adjustable ranges from 16 inH2O to 1,450 psig via Hart®
    302 Series: adjustable ranges from 40 inH2O to 1,160 psig
    304 Series: adjustable ranges from 16 inH2O to 1,450 psig
  • Hart® signal output available on 301 & 304 Series Transmitters
  • 316 Stainless Steel wetted parts
  • Strong flush diaphragm with minimal fill volume
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • Meets the requirements for 3-A

  • 300/301 Series
    • Cable connection only (no housing)
    • Active temperature compensation
    • Fixed range (300 Series)
    • Range adjustment with Hart® (301 Series)
    • All polished Stainless Steel housing
    • 10:1 Turn down (301 Series)
  • 302 Series
    • All polished Stainless Steel housing
    • Active temperature compensation
    • Zero/span adjustable
    • 4:1 Turn down
  • 304 Series
    • All polished Stainless Steel housing
    • Active temperature compensation
    • Accuracy 0.1% of adjusted span
    • 10:1 Turn down
    • Easy programming and range adjustment without test pressure via on-board display
    • Hart® protocol available
    • If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

      SERIES        300 Fixed range transmitter 302 Adjustable transmitter
      301 Adjustable transmitter with Hart® signal 304 Intelligent transmitter
      TRI-CLAMP SIZE 12 1-1/2″ 24 3″
      16 2″
      300 SERIES
      PRESSURE RANGES
      (Fixed)    
      40 inH2O 0 inH2O to 40 inH2O 120 inH2O 0 inH2O to 120 InH2O 15 0 psig to 15 psig
      60 inH2O 0 inH2O to 60 inH2O 5 0 psig to 5 psig 30 0 psig to 30 psig
      80 inH2O 0 inH2O to 80 inH2O 10 0 psig to 10 psig 60 0 psig to 60 psig
      301 SERIES
      PRESSURE RANGES
      ( Adjustable transmitter with HART® signal)
      16/160 inH2O 0 inH2O to 16 inH2O to 0 inH2O to 160 inH2O 14.5/145 0 psig to 14.5 psig to 0 psig to 145 psig 290/1450  0 psig to 290psig to 0 psig to 1,450 psig
      47/470 inH2O 0 inH2O to 47 inH2O to 0 inH2O to 470 inH2O 72.5/435 0 psig to 72.5 psig to 0 psig to 435 psig
      302 SERIES
      PRESSURE RANGES
      (Adjustable)
      40/160 inH2O 0 inH2O to 40 inH2O to 0 inH2O to
      160 inH2O
      14.5/58 0 psig to 14.5 to 0 to 58 psig 232/725 0 psig to 232 psig to 0 psig to 725 psig
      160/277 inH2O 0 inH2O to 160 inH2O to 0 inH2O to
      277 inH2O
      36/145 0 psig to 36 psig to 0 psig to 145 psig 580/1160 0 psig to 580 psig to 0 psig to
      1,160 psig
      277/609 inH2O 0 inH2O to 277 to 0 inH2O to
      609 inH2O
      100/232 0 psig to 100 psig to 0 psig to
      232 psig
      304 SERIES
      PRESSURE RANGES
      (Intelligent)
      16/160 inH2O 0 inH2O to 16 inH2O to 0 inH2O to
      160 inH2O
      14.5/145 0 psig to 14.5 to 0 psig to 145 psig 290/1450 0 psig to 290 psig to 0 psig to 1,450 psig
      47/470 inH2O 0 inH2O to 47 inH2O to 0 inH2O to
      470 inH2O
      72.5/435 0 psig to 72.5 psig to 0 psig to 435 psig
      ACCURACIES 1 0.2% of adjusted span *
      OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 43 4 mA to 20 mA, 2-wire and Hart® signal **
      ELECTRICAL CONNECTIONS† 25 M12x1 (4-pin) 71 PG9 Cable Gland
      28 1/2″ NPT Female
      CABLE LENGTHS†† 15P  15′ Polyurethane cable 30P 30′ Polyurethane cable
      OPTIONS JB Cable Junction Box TC Transparent Cover (for display) ***

      Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

      * Standard accuracy on the 304 Series is ±0.1% of adjusted span
      ** Required for the 301 Series, optional for the 304 Series
      *** Available for the 304 Series only
      † Available for the 302 and 304 Series only
      † † Additional cable lengths available, consult factory

      The NOSHOK 304-16-290/1450-1-1-71-30P-TC is an intelligent sanitary pressure transmitter with an adjustable range from 0 to 290 psig through 0 to 1,450 psig. It features a 2-inch tri-clamp process connection and 4 to 20 mA output.

      The transmitter includes an onboard display for viewing and configuring transmitter information. Its stainless steel wetted construction and sanitary process connection make it suitable for hygienic process applications.

      This configuration also includes a 30-foot polyurethane cable. The 304 Series is designed for sanitary pressure measurement and process monitoring applications requiring an adjustable pressure range and sanitary tri-clamp connection.

Reviews

There are no reviews yet.

Be the first to review “Noshok 304-16-290/1450-1-1-71-30P-TC Sanitary Transmitter”

Your email address will not be published. Required fields are marked *

Description

30 Series Sanitary Transmitter, Tri Clamp 2

30 Series Sanitary Transmitter, Tri Clamp 2”, Intelligent from 0 psig to 290 to 0 psi to 1450 psig, 0.1% of adjusted span, 4-20 mA/2-wire, PG9 Cable Gland, 30′ Polyurethane Cable, Transparent Cover

deal for applications including tank level measurement, food & beverage, dairy, breweries, chemical processing and pharmaceutical.

  • 300 Series: ranges from 40 inH2O to 60 psig 
    301 Series: adjustable ranges from 16 inH2O to 1,450 psig via Hart®
    302 Series: adjustable ranges from 40 inH2O to 1,160 psig
    304 Series: adjustable ranges from 16 inH2O to 1,450 psig
  • Hart® signal output available on 301 & 304 Series Transmitters
  • 316 Stainless Steel wetted parts
  • Strong flush diaphragm with minimal fill volume
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • Meets the requirements for 3-A

  • 300/301 Series
    • Cable connection only (no housing)
    • Active temperature compensation
    • Fixed range (300 Series)
    • Range adjustment with Hart® (301 Series)
    • All polished Stainless Steel housing
    • 10:1 Turn down (301 Series)
  • 302 Series
    • All polished Stainless Steel housing
    • Active temperature compensation
    • Zero/span adjustable
    • 4:1 Turn down
  • 304 Series
    • All polished Stainless Steel housing
    • Active temperature compensation
    • Accuracy 0.1% of adjusted span
    • 10:1 Turn down
    • Easy programming and range adjustment without test pressure via on-board display
    • Hart® protocol available
    • If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

      SERIES        300 Fixed range transmitter 302 Adjustable transmitter
      301 Adjustable transmitter with Hart® signal 304 Intelligent transmitter
      TRI-CLAMP SIZE 12 1-1/2″ 24 3″
      16 2″
      300 SERIES
      PRESSURE RANGES
      (Fixed)    
      40 inH2O 0 inH2O to 40 inH2O 120 inH2O 0 inH2O to 120 InH2O 15 0 psig to 15 psig
      60 inH2O 0 inH2O to 60 inH2O 5 0 psig to 5 psig 30 0 psig to 30 psig
      80 inH2O 0 inH2O to 80 inH2O 10 0 psig to 10 psig 60 0 psig to 60 psig
      301 SERIES
      PRESSURE RANGES
      ( Adjustable transmitter with HART® signal)
      16/160 inH2O 0 inH2O to 16 inH2O to 0 inH2O to 160 inH2O 14.5/145 0 psig to 14.5 psig to 0 psig to 145 psig 290/1450  0 psig to 290psig to 0 psig to 1,450 psig
      47/470 inH2O 0 inH2O to 47 inH2O to 0 inH2O to 470 inH2O 72.5/435 0 psig to 72.5 psig to 0 psig to 435 psig
      302 SERIES
      PRESSURE RANGES
      (Adjustable)
      40/160 inH2O 0 inH2O to 40 inH2O to 0 inH2O to
      160 inH2O
      14.5/58 0 psig to 14.5 to 0 to 58 psig 232/725 0 psig to 232 psig to 0 psig to 725 psig
      160/277 inH2O 0 inH2O to 160 inH2O to 0 inH2O to
      277 inH2O
      36/145 0 psig to 36 psig to 0 psig to 145 psig 580/1160 0 psig to 580 psig to 0 psig to
      1,160 psig
      277/609 inH2O 0 inH2O to 277 to 0 inH2O to
      609 inH2O
      100/232 0 psig to 100 psig to 0 psig to
      232 psig
      304 SERIES
      PRESSURE RANGES
      (Intelligent)
      16/160 inH2O 0 inH2O to 16 inH2O to 0 inH2O to
      160 inH2O
      14.5/145 0 psig to 14.5 to 0 psig to 145 psig 290/1450 0 psig to 290 psig to 0 psig to 1,450 psig
      47/470 inH2O 0 inH2O to 47 inH2O to 0 inH2O to
      470 inH2O
      72.5/435 0 psig to 72.5 psig to 0 psig to 435 psig
      ACCURACIES 1 0.2% of adjusted span *
      OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 43 4 mA to 20 mA, 2-wire and Hart® signal **
      ELECTRICAL CONNECTIONS† 25 M12x1 (4-pin) 71 PG9 Cable Gland
      28 1/2″ NPT Female
      CABLE LENGTHS†† 15P  15′ Polyurethane cable 30P 30′ Polyurethane cable
      OPTIONS JB Cable Junction Box TC Transparent Cover (for display) ***

      Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

      * Standard accuracy on the 304 Series is ±0.1% of adjusted span
      ** Required for the 301 Series, optional for the 304 Series
      *** Available for the 304 Series only
      † Available for the 302 and 304 Series only
      † † Additional cable lengths available, consult factory

      The NOSHOK 304-16-290/1450-1-1-71-30P-TC is an intelligent sanitary pressure transmitter with an adjustable range from 0 to 290 psig through 0 to 1,450 psig. It features a 2-inch tri-clamp process connection and 4 to 20 mA output.

      The transmitter includes an onboard display for viewing and configuring transmitter information. Its stainless steel wetted construction and sanitary process connection make it suitable for hygienic process applications.

      This configuration also includes a 30-foot polyurethane cable. The 304 Series is designed for sanitary pressure measurement and process monitoring applications requiring an adjustable pressure range and sanitary tri-clamp connection.